REVAMPS

The KLAREN self-cleaning heat exchange technology offers the possibility of revamping existing vertical conventional severely fouling exchangers into a self-cleaning configuration. Much interest has arisen for the revamp of severely fouling reboilers, evaporators and crystallizers. In general, the requirements for the majority of revamps can be summarized as follows:

  • The same process conditions should be maintained.
  • The connections to the column or flash vessel should be maintained.
  • The installed pumps should be used.
  • The existing channels should also be re-used where possible.
  • The revamp must be carried out within the available space.

A typical example for the revamp of an existing reboiler into a KLAREN self-cleaning configuration is shown in the figures 1 and 2.

appl&poss_fig1K.gif - 16814 Bytes   appl&poss_fig2K.gif - 26729 Bytes
Figure 1: Conventional reboiler.   Figure 2: Conventional reboiler after revamp.


Print

Previous Page Please Read the Disclaimer Next Page